Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/01/2006 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 11/03/2006 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* APPEARS VIOLATION IS FOR A GARAGE BUILT W/OUT A PERMIT ON PROPERTY LINE. OWNER NEEDS TO OBTAIN A PERMIT PROVIDING A SITE DRAWING SHOWING HOW GARAGE IS BUILT AND OF WHAT MATERIALS, PLAN TO SHOW ELECT, PLUMB AND MECH IN GARAGE. ELECT 1. ALL ROMEX BELOW 8' TO BE PHYSICALLY PROTECTED. 2. MUST BE A SWITCH TO DISCONNECT ALL CIRCUITRY OFF FROM GARAGE ON GARAGE WALL INSIDE OR OUTSIDE. 3. RECEPTACLES INSIDE TO BE GFI PROTECTED. 4. SHOW ALL OTHER ELECTRICAL USES. NOTE TO OFFICE: ISSUE TO GENERAL INSPECTOR ALL PERMITS FOR THIS GARAGE. |