Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - SERVICE UPGRADE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/19/2006 | ELECTRIC - SERVICE UPGRADE | Approved | IVRS - Inspection :* OK TO CLEAR |
|
| 12/13/2006 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. GROUND WIRES IN ALL BOXES TO HAVE WIRE NUTS - NOT JUST BEING TWISTED TOGETHER. 2. COVERS FOR DEVICES FOR MICROWAVE & DISPOSAL. 3. WATER HEATER NOT DISCONNECTED 4. O/S FRONT LIGHT MISSING 5. COOLER SW WIRING TO BE PROTECTED IN FURN. ROOM & BROKEN COVER. 6. NO SMOKE DETECTORS - THEY ALSO MUST BE INTERLOCKED 7. INSTALL LIGHTING IN CLOSETS - MUST MEET NEC REQUIREMENTS. 8. GFI IN BATHROOM MUST BE WIRED IN #12 WIRE 9. PLAN SHOWS O/S WASHER & DRYER CIRCUITS -- NEC & IRC REQUIRED 10. STILL NEED LICENSED CONTRACTOR VERIFICATION 11. NO COOLER BOX |
|
| 12/11/2006 | ELECTRIC - SERVICE UPGRADE | Partial Approval |