Inspection History Details
Inspection Status: Denied
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/30/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* SEE NOTES LAST INSP. A REINSPECTION FEE WILL BE ASSESSED NEXT INSPECTION IF NO COMPLIANCE. |
|
| 09/13/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. RISER CONDUCTORS NOT MARKED ON INSULATION REQUIRED BY CODE, MUST BE SUNLIGHT RESISTANT. 2. SYSTEM NOT GROUNDED PER CODE. WIRING METHOD FOR 240V OUTLET & PVC CONDUIT TERMINATION NOT PER CODE. ALSO, SERVICE WAS RELOCATED FROM INSIDE ADDITION TO OUTSIDE, PROVIDE DOCUMENTS FOR PASSED INSPECTIONS APPROVALS & PERMIT FOR WORK DONE. IF NOT, OBTAIN PERMIT FOR SERVICE RELOCATE AND WIRE SYSTEM PER CODE, RECALL INSPECTION. |