Permit: T06EL01787

Parcel: 134080050

Inspection Status: Partial Approval

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
08/01/2008 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1) ISOLATE NEUTRALS AND GROUNDS IN SUB PANEL
03/21/2007 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1) GROUND METAL 12 X 12 X 4 JB PER 250.4 AND SIZE GROUND WIRE PER 250.122
2) SPLIC CONDUCTORS IN 12 X 12 X 4 JB PER NEC 110.14
3) SECURE LIQUID TIGHT FLEX PER NEC 356.30
4) INSTALL ADDRESS LABEL
5) BOND WATER AND GAS LINE TO SERVICE
6) INSTALL BUSHING AT SEAL TITE TO PROTECT WIRES PER NEC 300.4 (F)
02/28/2007 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*