Inspection History Details
Inspection Status: Denied
Inspection History: ELECTRIC - FINAL
Permit Number - T06EL01783
Inspection Description - ELECTRIC - FINAL
Inspection Status - Denied
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/06/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. NEED LIGHT OR SWITCHED RECEPTACLE IN LIVING ROOM 2. BACK PORCH LIGHT NOT WORKING 3. ALL KITCHEN COUNTER RECEPTACLES NEED GFI PROTECTION. 4. INSTALL RANGE ANTI-TIP DEVICE -- SEE RANGE INSTRUCTIONS. 5. NEED PROPER CONNECTOR FOR HOOD WIRING. 6. PANEL DIRECTORY NOT IDENTIFIED. 7. HVAC SYSTEM NOT WORKING. 8. WHERE IS WATER HEATER/AIR HANDLER - PROVIDE ACCESS TO AND PLANS FOR WORK DONE. |
|
09/08/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. UNIT NUMBER STILL NOT POSTED ON UNIT. 2. AN ELECTRICAL PERMIT MUST BE ISSUED FOR INSPECTION OF NEW WIRING IN UNIT, AS IS THROUGHOUT COMPLEX. 3. REINSPECTION FEE TO BE PAID PRIOR TO FINAL APPROVAL. |
|
09/06/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* POST UNIT NUMBER HAVE DOOR UNLOCKED FOR INSPECTION |