Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - SERVICE UPGRADE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/19/2006 | ELECTRIC - SERVICE UPGRADE | Approved | ||
| 09/12/2006 | ELECTRIC - SERVICE UPGRADE | Partial Approval | IVRS - Inspection :* 1) JUMPER FROM WATER TO GAS TO BE KEARNEYS #4 RATHER THAN RUN UNDER EXISTING CLAMP 2) JUMPER TO 2 1/2" BOND BUSHING TO BE #4 3) NEUTRAL IN J-BOX TO HAVE SAME SIZE SPLICE RUNING TO PANEL 4) USE ROMEX CONNECT UNDER PANEL TO CLOSE OFF OPENING WHERE GROUND ENTERS 5) SPLICE IN TEP SIDE OF METER ENCLOSURE SUBJECT TO TEP 6) TIE IN ADDITIONAL CIRCUITRY IN TO SERVICE 7) OVER FILLED J-BOX, REMOVE EXCESS WIRING AND ALLOW COVER TO BE REMOVED FREELY 8) GROUNDING ELECTRODE CONDUCTOR HAS TO BE RUN CONTINOUS INTO GROUND BAR IN PANEL |