Permit: T06EL01659

Parcel: 119041730


Addresses:

3512 S 9TH AV

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
11/22/2006 ELECTRIC - FINAL Approved IVRS - Inspection :*
11/21/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
SEE NOTES LAST INSP.
11/17/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
GROUND RODS NEED TO BE 6' APART
GROUND WATER & GAS
11/14/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. #12 GROUND, #10 NEUTRAL TO SMALL FOR FEEDERS INTO NEW SUB-PANEL BY SERVICE #6 FEEDERS RAN TO BLD. BUT #12, #10 TO SUB-PANEL AHEAD OF BLD?
2. 2 GROUND RODS REQUIRED AT BLD. BOND WATER & GAS PIPING.

ART. 250.32, 250.50, 250.104 NEC
ALSO, ART. 310 NEC
11/07/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. ITEM #'S NOT CORRECTED FROM PERMIT OBTAINED 2001 T01EL01771 PERMIT EXPIRED, MAKE CORRECTIONS.
2. INSIDE PANEL CANNOT BE INSIDE KITCHEN CABINET, RELOCATE.
3. KITCHEN OUTLET ABOVE STOVE TO BE GFI PROTECTED.
4. MC CABLE INSTALL AT WALL NOT PER CODE.
5. OUTSIDE RECEPTS. BY WATER HTR. MUST BE GFI PROTECTED.
6. PROPERLY ABANDON 3/4" CONDUIT ON ROOF OVERHANG.
7. QUALIFIED ELECTRICIAN TO CHECK OUT SYSTEM PER NOTE, PROVIDE LETTER STATING SYSTEM IS SAFE & OPERABLE.