Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T06EL01488
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/09/2006 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
08/08/2006 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1) FINISH HOOD #101 |
|
08/05/2006 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1) FOR UNIT #101: 2 CIRCUITS IN KITCHEN TO SERVE COUNTER TOPS 2) CORD NOT ALLOWED FOR PERMANENT WIRING FOR UNITS #105 & #111 AND 2 KITCHEN CIRCUITS |
|
08/02/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* #111, 101 1. INSTALL RANGE PLUG TO WALL 2. INSTALL SMOKE DETECTORS IN BEDROOMS 3. NEED A CONNECTOR FOR HOOD 4. WHERE ARE KITCHEN GFI'S 5. GROUNDED RECEPTACLES ON UNGROUNDED SYSTEM 6. GROUND RECEPTACLES WITH GROUND WIRE 7. EXPOSED NM CABLE OUTSIDE (101) #121 1. INSTALL RANGE PLUG TO WALL 2. PLEASE VERIFY 2 CIRCUITS SERVING KITCHEN COUNTER TOPS. 3. GROUNDED RECEPTACLES ON UNGROUNDED SYSTEM 4. GROUND RECEPTACLES WITH GROUND WIRE #105 1. MISSING COVER PLATE FRONT PORCH 2. INSTALL RANGE PLUG TO WALL 3. PLEASE VERIFY 2 CIRCUITS SERVING KITCHEN COUNTERTOPS. 4. WE HAVE A HIDDEN SPLICE TO HOOD ALSO CANNOT USE EXTENSION CORD FOR WIRING METHOD. 5. GROUNDED RECEPTACLES ON UNGROUNDED SYSTEM 6. GROUND RECEPTACLES WITH GROUND WIRE. |