Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/23/2006 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* 1) OWNER TO REPAIR O/S COOLER FEED-DO NOT USE TILL REPAIRED OR REMOVED |
|
| 07/25/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. CUT & EXPOSED ROMEX WIRING ABOVE COOLER TERMINATE IN APPROVED WEATHERPROOF BOX & COVER EAST SIDE OF HOUSE OR REMOVE. 2. EXPOSED WIRING ON SOUTH SIDE OF HOUSE BY WINDOW COOLER, MUST BE IN RACEWAY BELOW ROOF LINE FOR PHYSICAL PROTECTION. 3. OUTSIDE RECEPTACLE IN FRONT PORCH MUST BE GFI PROTECTED & IN APPROVED WEATHERPROOF BOX & COVER 4. NEED ACCESS INSIDE, HOUSE LOCKED, CALLED PA# PER REQUEST, NO ANSWER, LEFT MESSAGE. INSP. NOT MAKING APPOINTMENTS AT THIS TIME DUE TO WORKLOAD - RECALL INSP. 5. BE SURE ALL COVERS FOR RECEPTS & SWITCHES ON - SMOKE DETECTORS. |