Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/13/2006 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* 1. PROVIDE A FLAT STANDABLE SURFACE BELOW SERVICE 3' OUT & 30" WIDE. 2. GROUND RODS TO BE BELOW GRADE USE ALL BRASS TYPE CLAMPS. 3. STRAP GROUNDS BELOW SERVICE TO WALL. 4. STRAP CONDUITS ABOVE SERVICE WITHIN 3' OF PANEL, USE MIN 1/4" HARDWARE ON RISER. 5. NO CONDUCTORS IN SERVICE RACEWAY 6. ALL NEW WIRING COMING OUT OF HOUSE ANY INSPECTIONS ON THIS WORK OR PREVIOUS PERMIT. |