Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/03/2006 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 07/05/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The service is not per code.| 210* 1. HAVE WATER ON INTERIOR OF PANEL AND ALONG BRANCH CKT CONDUCTORS GOING INTO BREAKERS? IT RAINED EARLIER CHECK PANEL AND HUBS/RACEWAYS. 2. PROVIDE GFI PROTECTION FOR POOL LIGHT. 3. GROUNDS AND NEUTRALS MUST BE SEPARATED IN SUB-PANEL AND ENCLOSURE GROUNDED WITH EQUIPMENT GROUND - NOT NEUTRAL. |
|
| 06/30/2006 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1. SEALING DEVICE AT ENTRANCE ABOVE CURRENT CARRING PARTS. 2. WHY 2 GROUNDS ON UF CABLE. |