Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06EL01064

Parcel: 113051170


Addresses:

3440 N MOUNTAIN AV

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
06/16/2006 ELECTRIC - FINAL Approved IVRS - Inspection :*
06/05/2006 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1) INSTALL BREAKER BLANKS
2) INSTALL GUY KIT FOR MAST
3) SECURE BOND WIRE OVER ROOF
4) IDENTIFY PANEL DIRECTORY
5) FIX FRONT COVER SO IT OPENS EASILY
6) SECURE MAST TO STRUCTURE (STRAPS ARE LOOSE)