Permit: T06EL00940

Parcel: 127040890


Addresses:

5044 E 2ND ST

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
05/31/2006 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
05/19/2006 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SMOKE DETECTORS REQUIRED IN BEDROOMS - BATTERY
2. EXPOSED ROMEX BELOW 8' IN CLOSET AND IMPROPERLY RUN TO LIGHT WITH NO BOX BEHIND IT (SOUTH CLOSET).
3. NORTH CLOSET -- WIRE RUN DIRECTLY TO FIXTURE -
NEEDS BOX
4. KITCHEN RECEPTACLE TO BE GFI PROTECTED.
5. STORAGE ROOMS & LAUNDRY ALL EXPOSED WIRING BELOW 8' TO BE PHYSICALLY PROTECTED.
05/18/2006 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
FRI 9:30 AM SOMEONE THERE FROM VAIL