Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T06EL00879
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/07/2008 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
02/06/2008 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* WORK NOT COMPLETE RENE 850-4632 |
|
02/05/2008 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
02/01/2008 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* CANCELED |
|
01/31/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. REMOVE TEMP POWER RECEPTACLE OR INSTALL AS PER CODES 2. #8 NM CABLE AMPACITY TO BE AS PER 334.80 3. INSTALL BOND LUG TO BUSHING 4. SECURE CABLES TO BOX 312.5(C) 5. FINISH PREVIOUS ITEM #1 6. WHERE ARE WATER & GAS BONDS |
|
01/29/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. IDENTIFY WHITE WIRE USED AS PHASE CONDUCTOR PROPERLY 2. INSTALL BREAKERS LISTED FOR USE IN SIEMENS PANEL 3. RECALL BOTH PERMITS @ SAME TIME WHEN READY FOR FINAL ON ACTIVITY T07CM03500 |
|
09/18/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SERVICE DOOR DOES NOT CLOSE PROPERLY 2. NEED AN EQUIPMENT GROUND TO OLD J-BOX DISCONNECT, NEUTRALS AND GROUNDS TO BE SEPARATED (PROVIDE LADDER FOR INSPECTION) 3. CORRECTLY IDENTIFY PANEL DIRECTORY - DON'T ABBREVIATE 4. J-BOX UNDER PANEL IS OVERFILLED AND NEEDS MINIMUM #12 CU GROUND TO BOX PARTIAL INSPECTION - PROVIDE INTERIOR ACCESS |
|
06/02/2006 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1) EXPOSE GROUND RODS 2) IDENTIFY PANEL DIRECTORY |