Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T06EL00794
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/22/2006 | ELECTRIC - INTERMEDIATE | Approved | ||
04/28/2006 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The service is not per code.| 210* 1. SERVICE CONDUCTORS NEED TO BE SUNLIGHT RESISTANT NEC 310.8(D) 2. MAST NEEDS TO BE BONDED NEC 250.92 3. SERVICE GUTTER NEEDS TO BE BONDED NEC 250.92 *NOTE* THIS TYPE OF MYERS HUB NOT APPROVED FOR SERVICE SIDE BONDING - NEC 250.92(B) 4. BOND GAS PIPE TO SERVICE - NEC 250.104(B) 5. SERVICE 825 BLOCK 827'S PANEL COVERING FROM OPENING TO 90 DEGREES. 6. IF SEPARATE PIPE SYSTEMS (I.E. WATER & GAS) MAKE SURE ALL ARE BONDED TO SERVICE - NEC 250.104 |