Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/19/2006 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
| 04/14/2006 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 04/12/2006 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SMOKE DETECTOR MISSING, MUST BE INSTALLED AND OPERATIONAL. 2. INSIDE SUB-PANEL, CONDUIT WHICH BRINGS IN FEEDERS FROM SERVICE HAS PULLED OUT FROM ATTACHING TO PANEL MUST RE-ATTACH TO PANEL AND LOCK NUT INSTALLED. 3. SEAL LARGE HOLE IN SUB-PANEL & REPLACE SCREWS MISSING WHICH COVER IT. 4. EQUIPMENT GROUND COMING INTO SUBPANEL FROM SERVICE CANNOT TIE INTO NEUTRAL BAR THIS MAY TRANSFER CURRENT INTO EQUIPMENT GROUND - ISOLATE GREEN WIRE AND PROPERLY ATTACH TO GROUND. 5. 30 AMP - 240 VOLT RECEPTACLE BY GATE TO HAVE A WEATHERPROOF COVER SINCE OUTSIDE. |