Permit: T06EL00520

Parcel: 135041590


Addresses:

7058 E CALLE CANIS

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
05/24/2006 ELECTRIC - FINAL Approved IVRS - Inspection :*
05/22/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
USE PROPER FITTING (SUCH AS CHASE NIPPLE OR SHORT NIPPLE) AT LB - PANEL CONNECTION AT BOTTOM OF PANEL.
05/11/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. USE ONLY SQ.D. BREAKERS IN THIS PANEL.
2. USE PROPER FITTING FOR 1" LB CONNECTION TO PANEL.
3. INSTALL BOND BUSHING WHERE REDUCING WASHERS USED AT A.C. ENTRY INTO PANEL.
4. ID NEUTRAL AT WEATHER HEAD.