Permit: T06EL00283

Parcel: 117071450


Addresses:

606 S HERBERT AV


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T06EL00283

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/05/2010 ELECTRIC - FINAL Approved IVRS - Inspection :*
07/19/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* ALL PREVIOUS INSPECTION REPORTS TO BE ON SITE AND AVAILABLE TO INSPECTOR. RESCHEDULE WITH CONTACT NAME & PHONE NUMBER. A FEE MAY BE ASSESED AT NEXT INSPECTION
07/15/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
07/13/2010 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
06/16/2010 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
06/16/2010 ELECTRIC - FINAL Partial Approval
06/14/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1 - SECURE CABLES TO BOXES
2 - USE APPROVED SPLICE CONNECTORS FOR CONDUCTORS
3 - BOXES MORE THAN 1/4 3/420
4 - PROTECT BULB IN CLOSET
5 - FILL UNUSED OPENINGS IN BOX - NOT FITTINGS
6 - NEED A DISCONNECTING MEANS FOR WATER HEATER
7 - STRAP GROUND TO BONDING
8 - NM CABLE #8 TO BREAKER CAPACITY

** WILL NEED A PLUMBING PERMIT FOR WATER HEATER RELOCATION **
06/03/2010 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1) OPEN NEW RECEPTS TO INSPECT
2) FINISH UPGRADE
3) ANSWERED CONTRACTOR QUESTIONS
05/27/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING SERVICE ENTRANCE CONDUCTORS
2) SUPPORT AQLL RACEWAYS ABOVE PANEL
3) NEED GAS AND WATER BOND
4) LOAD CONDUCTORS NOT TO EXIT THRU TOP END WALL
5) RECONNECT PERMIT T02EL00514 NEEDS TO BE RE-OPENED
6) HAVE QUALIFIED ELECTRICAL CONTRACTOR PERFORM WORK