Permit: T06EL00261

Parcel: 126030890

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
06/07/2006 ELECTRIC - FINAL Approved IVRS - Inspection :*
1) RECEIVED CHECK #1049 $108.00 AFTER HOURS INSPECTION
06/06/2006 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
CONTRACTOR WORKING ON JOB.
05/12/2006 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
MEET WITH CONTRACTOR TO DISCUSS JOB
04/24/2006 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
OK TO COVER CONDUIT
1. OLD PANEL NOT ALLOWED AS A JUNCTION BOX USE AN APPROVED BOX.
2. WE HAVE BOX OVERFILL AND EXPOSED CONDUCTORS IN LAUNDRY ROOM.
3. WHAT ARE WE DOING WITH NM CABLE EXPOSED IN LAUNDRY ROOM?
4. FINISH PREVIOUS ITEMS 3, 5, & 6
03/30/2006 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1. SUPPORT RISER WITH 1/4" MINIMUM HARDWARE NOT DRYWALL SCREWS.
2. MAINTAIN CLEARANCES FROM GAS VENT 3'
3. LABEL BREAKERS.
4. PLEASE UNCOVER CONDUIT TO UNIT #2 FOR INSPECTION.
5. VERIFY DERATING OF CONDUCTORS PER 310.15
6. TIGHTEN LOOSE FITTINGS
7. PLEASE VERIFY CONNECTIONS AT UNIT #2 TO CHECK IF NEW OR EXISTING CIRCUITS.