Inspection History Details
Inspection Status: Partial Approval
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/10/2006 | ELECTRIC - RECONNECT | Partial Approval | IVRS - Inspection :* 1) OK TO CLEAR FOR CONSTRUCTION POWER 2) ALL ELECTRICAL WIRING TO HOUSE DISCONNECTED AT PANEL AND 1 CIRCUIT TO A GFI PROTECTED RECEPTACLE INSTALLED FOR CONST. ANY NEW WIRING REQUIRES A PERMIT |
|
| 01/04/2006 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GROUND WIRES AND NEUTRALS TO BE ISOLATED IN SUB-PANEL 2) SOME 2-WIRE CIRCUITS IN SUB-PANEL MUST ONLY FEED 2 WIRE RECEPTACLES 3) WATER HEATER ROOM-INSTALL LIGHT, PHYSCIALLY PROTECT ROMEX, STORAGE ROOM-PROTECT ROMEX UP TO 8' 4) SMOKE DETECTORS REQUIRED IN SLEEPING AREAS 5) ALL DEVICE PLATES TO BE INSTALLED 6) CLOSET LIGHT TO BE RE-SECURED 7) KITCHEN COUNTER RECEPTACLES TO BE GFI PROTECTED 8) BATHROOM RECEPTACLE TO BE GFI PROTECTED 9) RE-SECURE GROUND TO WATER LINE AND RE-CLAMP 10) BOND GAS LINE 11) REMOVE WIRING IN PLAY HOUSE AND ORANGE CORD AT BACK PORCH 12) WEATHER PROOF ROOF OUTLETS 13) REMOVE OUTSIDE WIRING EAST SIDE AND ? RECEPTACLE 14) CORRECT NORTH PORCH LIGHT WIRING |