Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case: T06DV01148

Parcel: 106120360

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
08/25/2006 INSP - INITIAL CODE ENFORCMENT Approved VISITED SITE, MET A TENANT, DID AN INSPECTION ON UNIT #8 AND FOUND THAT SEWAGE WAS PLUGGED CONTACTED OWNER AND OWNER MET WITH ME ON SITE. START INSPECTION ON ENTIRE MOBILE HOME PARK AND FOUND MULTIPLE VIOLATIONS, ELECTRICAL, PLUMBING, WEEDS, AND GRASS, TRASH AND DEBRIS, JUNKED MOTOR VEHICLES, EXPLAINED TO OWNER THAT THEIR WAS A NOTICE OF VIOLATIONS TO FOLLOW FOR THE VIOLATIONS. SEWER INE PLUGGED, SERVICE ENTRANCE- EXPOSED ROMEX, TO OPEN LINE PERMANENTLY ATTACHED, NO DEAD FRONT NO ID, LIVE OVERFUSED AT 50 ? RATED 30 ? GAS METER NOT LEGAL. WATER LINE EXPOSED NOT INSULATED AND NOT CONNECTED PROPERLY GRASS AND WEEDS. 3 VEHICLES AND TRASH.
08/25/2006 INSP - INITIAL CODE ENFORCMENT Approved SERVICE POLE #1
OVERSIZED WIRES, DISCONNECT REQUIRED AT MTR#16854124
DISCONNECT REQUIRED AT MTR#19173646
ID OF ?. 2 LIFE LINES, NO TWO LINES, SERVICE DISCONNECTED.
08/25/2006 INSP - INITIAL CODE ENFORCMENT Approved MOBILE #1
TRASH AND DEBRIS SHOPPING CARTS
W/H NOT ENCLOSED, NEEDS METAL
WATER LINES TO W/H EXT W/ LINES NO INSULATION
ELECTRIC LITE FIXTURE PORCH LITE
GAS LINE.
08/25/2006 INSP - INITIAL CODE ENFORCMENT Approved UNIT 2
LIFE LINE NOT W/H RATED OUTSIDE CITE FED BY EXT CORD
REFRIDGERATOR WITH DOOR
EXT CON ON WASHING MACHINE
DATA TAG
16 GAUGE ENERGIZING W/H
08/25/2006 INSP - INITIAL CODE ENFORCMENT Approved 180 DAY BOARD UP
#3
NOT OCCUPIED
GAS METER NOT MARKED TO WHAT IT FEED.
WATER LINES NOT INSULATED AND PROPER ELECTRIC CONNECTIONS ON SOUTH SIDE OPEN AND EXPOSED AND LAYING ON GROUND.
W/H ELECTRIC LINE ROMEX
ID NOT LISTED FOR PEDESTAL
GRASS AND WEEDS
SWAMP CODE, ZIP CORD, WEATHER PROFF BOX TAPED UP, NO ?.
08/25/2006 INSP - INITIAL CODE ENFORCMENT Approved #4 VACANT
FEEDER CONDU-IMPROPER WIRING METHODS UNSUPPORTED BOXES IN CONDUIT.
40 AMP BREAKER ON 30 AMP SYSTEM
BOX OVERFILLED WITH ELECTRICAL WIRES CONDUIT BOX BROKEN.
TWO LINES ON SUPPLY AT TRAILER
WATER LINES EXPOSED AND NOT INSULATED
GRASS AND WEEDS
GAS LINE NOT UP TO STANDARD FROM METER, GAS LINE NOT UP TO STANDARD FROM METER GAS LINE LAYING ON GROUND AND NO LISTING FLEX NOT LISTED FOR WHAT. ILLEGAL CIRCUIT PERMITS FEEDING SWAMP COOLER, DOOR HAS LOCKS ON OUTSIDE
W/H NOT APPROVED ON PERMITS
SHED HAS ELECTRICAL- REMOVE.
08/25/2006 INSP - INITIAL CODE ENFORCMENT Approved TRASH AND DEBRIS- STORAGE DISCONNECT, NO LABELING ON METER W/H NO PERMITS, WATER NO INSULANT, GAS METER NOT LEGAL, NO ID, AT SERVICE OR AT UNIT.
TWO VEHICLES NOT UP TO CODE.
08/25/2006 INSP - INITIAL CODE ENFORCMENT Approved H/W NO PERMITS, GAS METER NOT LEGAL, LIFE LINE ILLEGAL, NOTTERMINATED AT SERVICE BOX.
OVER FUSING 60AMP BREAKER SHOULD BE 30 AMP
LOCKING HASP ON EXTERIOR.
08/25/2006 INSP - INITIAL CODE ENFORCMENT Approved #7
GAS METER NOT LEGAL
ELECTRICAL- PERMANENT FEED MAIN ATTACHED
OPEN ? AT METER BOX
CLEANACE FOR SERVICE ENTRANCE- SWAMP CODER
BACK DOOR NEEDS POSSIBLE MOVE ELECTRICAL SERVICE ENTRANCE.
WATER SUPPLIED @ GARDEN HOSE
NO LISTED ID NUMBER, ENTRANCE DOOR NOT TREATED WITH PAINT.
EXPOSED WATER LINES AND EXTENSIVE OPEN SPLICES AND DEBRIS AND ILLEGAL WATER LINE CONNECTION.
H/W NO PERMITS.