Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case: T06DV00740

Parcel: 106042640


Addresses:

310 E NAVAJO RD

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
07/14/2006 INSP - INITIAL CODE ENFORCMENT Approved DAN-TENANT SINCE NOV 1, TOMAS-OWNER.
DOOR WINDOW BROKEN, FRONT WINDOW PANE BROKEN, , CTRUCTURAL CRACKS IN ADOBE-PLASTER EXPOSED ADOBE AT FRONT DOOR. DOORS NOT WEATHER TIGHT. SUB-PANEL IN KITCHEN PANTRY DOUBLE LUGGED. OPEN GROUND ON THREE PRONZ CIRCUIT IN KITCHEN REST OF HOUSE 2 PRONE. REFRIGERATOR PLUGGED INTO ADAPTER, WATER HEATER INSTALLED W/O PERMIT, EXPOSED TO ELEMENTS, MOST LIGHT FIXTURES WITHOUT COVERS/GLOBES MISSING FACEPLATES FOR CONVENIENCE OUTLEST THROUGHOUT CRACKING VISIBLE IN ALL ROOMS, PATCHED BY TENANT. EXPOSED INSULATION IN HALLWAY, TILE CHIPPED/CRACKED IN HALLWAY, TENANT STATES AIR CONES IN FROM CRACKS.
ADOBE STUCCO SEPARATING CAUSING DETERIORATION TO ADOBE BRICKS, CORNER OF BUILDING (NE) LEANS. OCNTRACTOR AND OR STRUCTURAL ENGINEER WILL NEED TO EVALUATE EXTENT OF REPAIRS NEEDED. SAFE TO OCCUPY AT THIS TIME.