Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T06DV00655
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/14/2006 | INSP - INITIAL CODE ENFORCMENT | Approved | (R) #1- PORCH LIGHT MISSING PROTECTIVE COVER, /IVING ROOM WINDOW REPLACED, RAW EXPOSED WOOD COOLER CORD GOES DIRECTLY THROUGH WALL METER SIDING SEWER VENT LINE NOT SECURED TO STRUCTURE APPROXIMATELY 3 FEET SEWERLINE EXPOSED. HWT LACKS COLD WATER SHUT OFF (ELECTRIC) HWT DOOR MADE BIGGER FRONT LIGHT INCONDESENT BULBS NO COVERS (R) #2- LACKS HAND RAILS ON STAIRS- FRONT/ REAR STAR TREDS BROKEN, SEWER VENT SHORT, APPROXIMATELY 2 1/2 INCHES IN HEIGHT BEDROOM WINDOW COVER WITH WOOD, 2ND OK HAS DOOR FOR EGRESS (R) #39- 27 FOOT EXPOSED SEWERLINE (O) #3- ADDED SEWER LINE WASHER/OPEN UNSEALED, (R) #4- FRONT DOOR STAIRS/ LIGHT FIXTURE MISSING GLOBE, COOLER STAND WOBBLY. HOT WATER REPLACED GAS TO ELECTRIC, NO COLD WATER SHUTOFF VALVE ELECTRIC JUNCTION BOX HANGING UNDER TRAILER, PROPANE TANK UNDER TRAILER. (O) #5- GATE LOCKED, WRONG MATERIAL USED AS FENCING (R) #6- HWT FLUE PIPE NOT SEALED AT JOINTS, NOT PROPERLY SECURED, FRONT DOOR STAIRS, REAR DOOR BLOCK FOR EGRESS. (R) #7- WATER SUPPLY LINE LEAKING AT CONNECTION B 6" BRANCH ON ROOF, SEWER LINE AT COOLER (R) #8- REAR DOOR LACKS STEPS FOR EGRESS, WASHER DRAINS ONTO GROUND (R) #9- VACANT: 40 AMP LIFELINE CORD 50 AMP BREAKERS #38- USED AS STORAGE #37- SHUTDOWN 6/1, OPEN UNSECURED (O) #10- ELECTRIC PEDESTAL LISTING, TRYING TO BE BRACED WITH 2 XD 4 LACKS 3 FOOT CLEARANCE (O) #11- COOLER STAND DETERIORATED, PEDESTAL, WRONG LIFE LINE, WRONG PLUG, FRONT COVER WILL NOT CLOSE, 2 LIFE LINE CONNECTED TOGETHER 1 - 40, 1.50 (R) #12- ELECT PEDESTAL CAN NOT GET TO SHED IN WAY LACKS 3' CLEARANCE STAIRS BROKEN, DOOR FRAME LACKS MOULDING OPEN STRUCTURE TO EXTERIOR ELEMENTS. EXTENSION CORD COMING TRHOUGH WINDOW FOR WASHER, OPEN SEWER LINE, WASHER DRAIN LINE, COOLER CONDUIT THROUGH METAL W/O BUSHING. BROKEN SMALL BEDROOM WINDOW. ELEC HOT WATER HEATER NO COLD S/O NOT WIRED CORRECTLY, FENCIND DETERIORATED-NOT SUPPORTED. (O) #13- FENCE MADE OF PLYWOOD GATE, TRASH & DEBRIS YARD EXTENSION CORD SUPPLYING ELECT TO OUTSIDE LITE, 2 VEHICLES. (R) #14- PORCH LITE MISSING PROTECTIVE COVER, PORCH STEPS PART BOARD, SEWER LEAK. (R) #15- WASHER DRAIN LINE, OPEN SEWER ADDED LINE, PEDESTAL LEAKS 3' CLEARANCE (LOC) OPEN SEWER LINE REAR. SUPPORTED BY WOOD 2 X 4 (O) #16- 40 AMP LIFE LINE, 50 AMP BREAKER, FENCE HELD UP W/SUPPORTS, REPLACED HW TO ELECT EXPOSED ROMEX, OPEN CONNECTIONS, LACK COLD WATER SHUT OFF NOT VISIBLE, PR.V. NOT VISIBLE. #24- NO HOME (O) #34- COOLER STAND HAZARDS, LEAKING WASHER USING EXTENSION CORD, HAZARDOUSLY SPLICED, DRAIN LINE DIRECT NO TRAPS, OPEN SEWER LINE, GROUND NET PEDESTAL GFCI O.O.O. SEWER LINE BRACED BY BLOCKS (R) #17- P.R.V MISSING, NEW TANK, DOG WASTE FENCE MADE OF WAFER WELD BOARD LISTING LEANING NOT PROPERLY SUPPORTED, SHED HAS ELECT LITE SWITCH, OUTLET, L/R WINDOW BROKEN, DOOR WINDOW BROKEN, WEEDS (EAST) TRASH & DEBRIS. (O) #18- WEEDS (EST) A/C STAND APPROX 7' HIGH DET PROPANE CONNECTED TO NATURAL GAS LINE ORFACES 50 AMP BREAKER, 40 AMP CORD, REAR DOOR-FENCE TOO FOR EGRESS. #19- ELECT PEDESTAL SUPPORTED BY WOOD STRINGERS (O) #20- NO HAND RAILS ON STEPS, WATER HEATER NOT ENCOLSED, MASTER DRAIN CONNECTED TO SEWER VENT ELECT CORD ON WEST REAR NEEDS SECURED (O) #21- NO ADDRESSING, WEEDS (O) #22- WEEDS, STORAGE OF COMBUSTIBLES UNDER TRAILER, CAT FECES, CARPORT PILLARS LEANING INCORRECTLY, NO HANDRAILS ON STEPS . WATER HEATER W.O.P. GAS LINE NOT CAPPED, IMPROPER WIRING, NO COLD WATER SHUT OFF. COPPER PILE IN SECTIONS, NO COVER. PROPANE TANK NOT SECURED, TOO CLOSE TO WINDOW. #22- INDOOR LIGHT FIXTURE ON CARPORT WITH EXTENSION CORD. CONT WEEDS OVER 6" #23- CARPORT W.O.P. 2" X 4" STRINGERS WATER DRAINS INTO VENT, NO TRAP EXTENSION CORD POWERS WASHER HOT WATER HEATER FLUE PIPE INCORRECT MATERIAL, NO COLD WATER SHUT OFF, PEDESTAL LACKS CLEARANCE, CORD THROUGH FENCE (R) #24- EXTENSION CORD POWERS WASHER NO TRAP, NO CLEARANCE ON ELECT PEDESTAL, CORD THROUGH FENCE (R) #25- 60 AMP BREAKER, 50 AMP CORD, LAMPS ON EAST ELEV. BAD MISSING DOORHANDLE, WINDOWS REPLACED, WRONG SIZE. STAIR W/O HANDRAILS, BACK DOOR SCREWED SHUT. ILLEGAL HASP, NO EGRESS. (R) #26- PEDESTAL CLEARANCE, CORD SPLICED, UNDER METAL SIDING, REAR DOOR HASP, STEPS DETERIORATED, NO RAILS, SEWER VENT CAPPED. STEPS INFERIOR, NO RAILS, EXTENSION CORD POWERS WASHER, NO TRAP VENT DOES NOT GO ABOVE ROOF, MAIN WATER SUPPLY LINE LEAKING, WRONG MATERIAL FOR FENCING. DOG WASTE. (R) #27- HOT WATER TANK-GAS TO ELECTRIC, EXPOSED RAMEX W.O.P., UP ON BLOCKS. SIDE WINDOWS BOARDED, IMPROPER HARDWARE ON BACK DOOR. TRASH & DEBRIS PEDESTAL LACKS CLEARANCE. CODER NOT WIPED PROPERLY. (R) #28- FENCING LEANING LACKS CLEARANCE ON PEDESTAL, CORD DAMAGED/TAMPERED WITH BACK DOOR. NEEDS STEPS/RAILS. CODER CONDUIT END NEEDS UPGRADE. (R) #29- OPEN/EXPOSED ELECT ON PORCH. WINDOW BOARDED, HOT WATER TANK-NO COVER, REPLACED GAS TO GAS.NO COLD WAT4R S/O. PEDESTAL LACKS CLEARANCE- 50 AMP BREAKER, 30 AMP CORD WITH SHARP DEBRIS ON TOP. FRAYED CODER ELECT W.O.P. NO CONDUIT, 2 SETS WIRES, GAS SHUT OFF BROKEN, STEPS TRASHED. DEBRIS & TRASH , SHED NOT STRUCTURALY SOUND, MUST REMOVE. BROKEN WINDOW IN LIVING ROOM, PLATSTIC REPLACES GLASS ON E. ELEV WINDOW, AWNING NEEDS REPAIR. (R) #30- COOLER STAN IS A REFRIGERATOR. BACK DOOR SEALED, NO STEPS/RAILS. MAIN WATER LINE REPLACED. PORCH UNSTABLE, STEPS W/O RAILS. HOT WATER HEATER EXPOSED ROMEX, GAS REPLACED WITH ELECT. WIRING UNSAFE AND EXPOSED PRESSURE RELIEF VALVE NOT PIPED. ACCESS TO TANK IMPLEDED. (R) #31- RAMP TO STEPS UNSTABLE, HASP ON OUTSIDE. CONDUIT THROUGH SIDING W/P BUSHING PLYWOOD ON BEDROOM WINDOW. 60 AMP BREAKER, 50 AMP CORD. BATHROOM WINDOW BROKE. WINDOWS ON E. ELEV COVERED/BOARDED. GARDEN HOSE FOR WATER MAIN, SHED DETERIORATED, TRASH & DEBRIS. (O) #32- REAR DOOR NO STEPS/RAILS, HASP ON EXTERIOR. WINDOW BROKEN, NO ELECT SERVICE. HASP ON FRONT DOOR W.O.P. REQUIRES CONDEMNATION MINIMUM HOUSING INSPECTION REQUIRED (R) #33- MISSING GLOBE ON PORCH LIGHT, REAR DOOR-HASP, BLOCKED, DOOR HANDLE, BROKEN. #34- DONE (O) #35- EMERGENCY SHUTOFF ON GAS METER NOT ACCESIBLE. NO GLOBE ON PORCH (R) #36- HASP ON BACK DOOR, NO RAILS. PEDESTAL SUPPORTED BY WOOD STRINGERS. |