Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T06DV00596
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/14/2006 | INSP - INITIAL CODE ENFORCMENT | Approved | VISITED SITE ON INITAL INSPECTION, MADE CONTACT WITH TENANT. INFORMED HER I WAS INSPECTOR FOR DNR FOLLOW ING UP ON HER COMPLAINT. TENANT ALLOWED ENTRY INTO STRUCTURE FOR MINIMUM HOUSING INSPECTION. TENANT STATED SHE RENTS SPACE FROM JACK HENSLEY, PARK OWNER AND TRAILER FROM ALBERTO BROKMAN WHO LIVES IN MEXICO, TENANT STATED TRAILER OWNER COMES IN ONCE A MONTH AND STAYS FOR A COUPLE OF DAYS IN TRAILER WITHOUT TENANT'S PERMISSION. TENANT HAS NO ADDRESS FOR OWNER. DNR INSPECTOR INFORMED HER SHE MUST HAVE ADDRESS FOR OWNER IN ORDER FOR DNR TO SEND NOTICE OF VIOLATION. TENANT DID PROVIDE CELL NUMBER FOR CONTACT WITH OWNER. CONDUCTED INSPECTION MINIMUM HOUSING AND WORK WITHOUT PERMITS ARE AS FOLLOWS: FIRE SAFETY 1)NO WORKING SMOKE ALARMS PRESENT HEATING SYSTEM 1)FURNACE WAS FOUND WITH LARGE AMOUNTS OF COMBUSTIBLE LINT AND DUST. 2) J- BOX IN FURNACE LACKS COVER PLATE. TENANT WAS USING SPACE HEATER COOLING 1)DOWN DRAFT COOLER VENT LACKING DEFASER UNIT. ELECTRICAL SYSTEM 1)TEST EQUIPMENT LURES USED ON ALL INTERIOR RECEPTACLES. TEST FOUND RECEPTACLES IN LIVING ROOM WITH NO CURRENT, 1 IN BEDROOM (MIDDLE) 2) SEVERAL RECEPTACLES THROUGH OUT STRUCTURE ARE LACKING COVER PLATES AND OTHER RECEPTACLES IN ILLEGAL ADDITION AND EAST BEDROOM WERE FOUND WITH BROKEN RECEPTACLES AND EXPOSED ELECTRICAL CONDUCTORS 3)LIFELINE CONNECTION AT ELECTRICAL PEDISTAL HAS EXPOSED ELECTRICAL CONDUCTORS, CONNECTION PLUG SHEETING HAS DETECHED FROM CORD TO PLUG 4)EXTERIOR LIGHT FIXTURES HANGING FROM ELECTRICAL CONDUCTOR AT NORTHEAST CORNER OF STRUCTURE. PLUMBING SYSTEM 1)BATHROOM SHOWER VALVES MISSING HANDLES AND ESCHSTION PLATES VISE GRIP USED TO TURN ON AND OFF 2)KITCHEN SINK LEAKING AT PLUMBING UNDERNEATH 3)EXTERIOR ABS 3 INCH PIPING HAS DETACHED AND ALLOWS GRAY WATER FROM KITCHEN SINK TO PUDDLE UNDER TRAILER. INTERIOR FEATURES 1)16X16 CERAMIC FLOOR TILES IN KITCHEN (APPROXIMATELY 6) ARE BROKEN EXPOSING SHARP EDGES 2)BEDROOM AND BATHROOM VINAL FLOORING HAS NOT BEEN MAINTAINED SEVERAL FLOOR TILES ARE MISSING , BROKEN AND PEELING UP 3)HALLWAY WOOD PANELING IS SPLINTERED AND COMING APART 4) INTERIOR DOOR JAMBS ARE SPLIT FROM TOP TO BOTTOM 5)EXIST DOOR ILLEGAL ADDITION BEDROOM IN A DELAPITATED CONDITION DOOR VENEER SPLINTERED AND HAS HOLES, NOT STRUCTURALLY SOUND. 6)NORTH BEDROOM DOOR LACKING PRIVACY HARDWARE 7)SEVERAL FLOOR VENTS MISSING THROUGHOU INTERIOR AND POSES A SAFETY HAZARD DUE TO UNSECURED OPENINGS 8)WATER DAMAGED CEILING THROUGHOUT STRUCTURE, SECTION OF CEILING IN SOUTH BEDROOM MEASURING APPROXIMATELY 3 FEET BY 5 FEET HAS DETACHED AND EXPOSING FIBER GLASS INSULATION. BEDROOM CEILING IN ILLEGAL BEDROOM HAS SPLIT OPEN APPROXIMATELY 8 FEET LONG AS WELL AS HALLWAY. BUILDING AND STRUCTURES EXTERIOR ROOFS 1)CORRUGATE GALVANIZED SUB ROOF HAS BEEN INSTALLED OVER TRAILERS ROOF, CHECK FOR PERMITS ACCESSORY STRUCTURE STORAGE SHED APPROXIMATELY 8 FOOT BY 8 FOOR LACKING PAINT COVER FOR WEATHER PROTECTION STAIRWAY DECKS AND PORCHES 1)STAIRS TO LANDING ARE NOT SECURED TO LANDING POSE A SAFETY HAZARD DUE TO WOBBLING AND NO HAND RAIL 2)LANDING MADE OF PLYWOOD HAVE HOLES APPROXIMATEL 8" BY 8" AND GIVE WAY IN SEVERAL AREAS, NOT STRUCTURALLY SOUND WORK WITHOUT PERMITS ILLEGALLY ATTACHED BEDROOM WITH ELECTRICAL TO MAIN STRUCTURE. ROOF MADE OFCORRUGATED GALVANIZED METAL AND SECTION APPROXIMATELY 12 FOOT BY 8 FOOT HAS SUBROOF MADE OF 2 BY 4 WOOD STRUDS. 2 BY 4 STUDS HAVE BEEN SCABED TOGETHER ON EXTERIOR T-1-11 WOOD PANELING AND HAS ATTACHED HARDWAR NAILED ON OUTSIDE. 2 BY 4 WOOD STUDS SPANNING OVER 8 FEET. |