Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T06DV00572
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/25/2006 | INSP - INITIAL CODE ENFORCMENT | Approved | NEALL - DOUG PINE OWNER APS CALL OUT TO 1600 E. ROGER RD #12 LYNN KURPIEWSKI FROM APS ON SITE. T.P.D. CALLED OUT TO REMOVE OWNER FOR HIS OWN PROTECTION. INSPECTION: SINGLE WIDE TRAILER 16' X 70' -NO FRONT DOOR, REMOVED BY OWNER (SHEET HANGING) -ALL FLOORING REMOVED FROM LIVING ROOM AREA. -DEBRIS THROUGHOUT KITCHEN AND LIVING ROOM. -HAS TO WALK TRHOUGH, NO CLEAR PATH. -KITCHEN CABINATS REMOVED -STOVE REMOVED -DEBRIS STACKED AGAINST WALL -2ND DOOR IN HALLWAY BLOCKED BY DEBRIS -MASTER BEDROOM AND 2ND BEDROOM WALLS REMOVED. -BATHROOM WALLS REMOVED, TOILET WORKING. -NO SHOWER, OR SINK FOR TOILET. -ROMEX PULLED OUT OF WALLS AND CEILING. -ELECTRICAL OUTLETS THROUGHOUT REAR BEDROOM EXPOSED. -OWNER USING ROMAX AND OUTLET IN HAZARDOUS WAYS. -CLOTHING HANGERS, HAZ. SPLICING, UNPROTECTED WIRING. HALLWAY IS CLOGGED WITH DEBRIS. NOT ABLE TO WALK THROUGH. -NO HEATER OR COOLER. -NO SMOKE DETECTORS -WINDOWS IN BEDROOM NOT FUNCTIONING. -DEBRIS BLOCKING WINDOWS (PANELING 2X4'S FORM M.H.) -DUE TO LACK OF EGRESS (DEBRIS) AND HAZ. WIRING PULLED ROMEX, CITY WILL POST AND ISSUE N.O.V. AND MANTAL -OWNER MIKE ON SITE TO BLANK OFF METER AND PARTIAL SECURE M.H. RECHEDULE 30 DAYS. |