Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case: T06DV00572

Parcel: 113010090


Addresses:

1600 E ROGER RD #12


Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Case Number - T06DV00572

Inspection Description - INSP - INITIAL CODE ENFORCMENT

Inspection Status - Approved

Date Description Inspector Results Comments
05/25/2006 INSP - INITIAL CODE ENFORCMENT Approved NEALL - DOUG PINE OWNER
APS CALL OUT TO 1600 E. ROGER RD #12
LYNN KURPIEWSKI FROM APS ON SITE.
T.P.D. CALLED OUT TO REMOVE OWNER FOR HIS OWN PROTECTION.
INSPECTION: SINGLE WIDE TRAILER 16' X 70'
-NO FRONT DOOR, REMOVED BY OWNER (SHEET HANGING)
-ALL FLOORING REMOVED FROM LIVING ROOM AREA.
-DEBRIS THROUGHOUT KITCHEN AND LIVING ROOM.
-HAS TO WALK TRHOUGH, NO CLEAR PATH.
-KITCHEN CABINATS REMOVED
-STOVE REMOVED
-DEBRIS STACKED AGAINST WALL
-2ND DOOR IN HALLWAY BLOCKED BY DEBRIS
-MASTER BEDROOM AND 2ND BEDROOM WALLS REMOVED.
-BATHROOM WALLS REMOVED, TOILET WORKING.
-NO SHOWER, OR SINK FOR TOILET.
-ROMEX PULLED OUT OF WALLS AND CEILING.
-ELECTRICAL OUTLETS THROUGHOUT REAR BEDROOM EXPOSED.
-OWNER USING ROMAX AND OUTLET IN HAZARDOUS WAYS.
-CLOTHING HANGERS, HAZ. SPLICING, UNPROTECTED WIRING.
HALLWAY IS CLOGGED WITH DEBRIS. NOT ABLE TO WALK THROUGH.
-NO HEATER OR COOLER.
-NO SMOKE DETECTORS
-WINDOWS IN BEDROOM NOT FUNCTIONING.
-DEBRIS BLOCKING WINDOWS (PANELING 2X4'S FORM M.H.)
-DUE TO LACK OF EGRESS (DEBRIS) AND HAZ. WIRING PULLED ROMEX, CITY WILL POST AND ISSUE N.O.V. AND MANTAL
-OWNER MIKE ON SITE TO BLANK OFF METER AND PARTIAL SECURE M.H.
RECHEDULE 30 DAYS.