04/05/2006 INSP - INITIAL CODE ENFORCMENT Approved CONTACTED OWNER BY PHONE, REQUESTED ON SITE MEETING TO REVIEW N.O.V. ISSUED BY ROLO HENDRIC. WALKED EXTERIOR AND INTERIOR OF STRUCTURE. INSPECTION FOUND ELECTRICAL AND EGRESS ISSUES. INSPECTION FOR COMPLAINCE FOR T01VL01493 ARE AS FOLLOWS
UHC 701.3 VIOLATION ABATED, NEW WINDOW PANES ALL BROKEN GLASS HAS BEEN REPAIRED. NEW WEATHER STRIPPING FOR ENTRY DOORS. SECURITY DOOR HAS BEEN CORRECTED
UHC 301 - NOT ABATED, OWNER HAS SECURED PERMIT # T06PL00559 AND HAS SCHEDULED PLUMBING CONTRACTOR TO COMPLETE REPAIRS. ALL REPAIRS AND FINAL INSPCECTION SHOULD BE DONE BY 4-10-06 COURT DATE.
UHC 505.7 VIOLATION ABATED, PLUMBING CONTRACTOR FOUND ROOTS IN MAIN LINE, ROOTS PROBLEM WAS REMOVED APPROX 1 YEAR AGO. TENANT STATED NO PROBLEM WIL BACKING UP OF SEWERS SINCE THEN.
INSPECTION OF STRUCTURE FOUND OTHER ISSUES SUCH AS ADDITION OF ELECTRICLA CIRCUITS OF EXTERTIOR 16-11 1&2
1) PORCH AREA ADDITION OF ELECTRICAL CIRCUIT LACK WEATHER PROOF COVER FOR RECEPTACLE, EXISTING RECEPTACLE CLOSE NOT COVER J-BOX
ELECTRICAL SYS.
2) ADDITION OF 220 CIRCUITS FOR ELECTRIAL DRYER AND ELECTRIC STOVE, EXTERIOR RECEPTACLE LACKS WEATHER PROOF COVER AND EXPOSED ELECTICAL CONDUCTORS COMING OUT OF HOT WATER HEATER ENCLOSURE FOR ELECTRIC STOOL LACKS REQUIRED INSTALLATION IN CONDUIT.
FIRE SAFETY
BEDROOM WINDOWS ARE INSTALLED WITH WROUGHT IRON ENCLOSURES LACKING QUICK RELEASE HARDWARE. THIS CONDITION POSES FIRE SAFETY ISSUE FOR THE OCCUPANTS IN CASE OF FIRE AND/OR PANIC.
MECHNICAL SYS. NO ISSUES
PLUMBING SYS TEM - NO ISSUES
EXTERIOR SURFACES - NO ISSUES
INTERIOR FEATURES - NO ISSUES
NO OTHER ISSUES NEEDED TO BE ADDRESSED. PICTURES WERE TAKEN. N.O.V. WAS ISSUED TO OWNER ON SITE, CONTACTED SUPERVISOR TO OK ABATEMENT TIME OF EGRESS ISSUES 30 DAY WILL BE GIVEN TO ADDRESS ELECTRICAL AND EGRESS ISSUES.