Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case: T06DV00310

Parcel: 136370530

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
03/29/2006 INSP - INITIAL CODE ENFORCMENT Approved VISITED SITE ON INITAL INSPECTION. APARTMENT COMPLEX IS GATED, ENTRY REQUIRES KEYS FOR LOCKS. WAS ABLE TO TAKE PICTURES OF FRONT SECTION OF STRUCTURE, APPEARS NEW COOLER RECENTLY INSTALLED, NO ISSUES WITH FACIA WINDOWS AND ENTRY DOORS. PAINT SURFACE FRONT IN GOOD SHAPE, CHECKED REAR SECTION OF PROPERTY. PROPERTY ARE TOWN HOMES WITH SMALL BACK YARDS FENCED WITH CARPORT. FENCING IN GOOD SHAPE AS WELL AS BACK YARD. MADE CONTACT WITH OCCUPANT THROUGH BACK OPENED ENTRY GATE. SHOWED OCCUPANT CITY ID AND OPENED DOOR. INFORMED OCCUPANT OF COMPLAINT AND ASKED IF SHE WOULD ALLOW ENTRY FOR A QUICK INSPECTION, OCCUPANT STATED NO. LEFT CARD WITH CONTACT NUMBER FOR OWNER AND REQUESTED OCCUPANT TO FORWARD MESSAGE. PICTURES WERE TAKEN OF FRONT AND BACK YARD, GAS SERVICE IS ON AS WELL AS ELECTRICAL EVIDENCED BY FRONT DOOR LIGHT ON. CONTACTED SUPERVISOR RSALDATE AND FORWARDED INFORMATION REQUESTED. EMAILING PICTURES WHEN RETURNING TO OFFICE, SUPERVISOR WILL REVIEW CASE BEFORE MOVING FORWARD AND WAIT FOR RESPONCE FROM OWNER.