Permit: T06CM06570

Parcel: 118220040


Addresses:

235 W 22ND ST #01

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
08/26/2010 FRAMING Approved IVRS - Inspection :*
06/03/2010 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
UNIT 1:
1) FIREBLOCK DROPS
2) PROVIDE 1" CLEARANCE WATER HEATER FLUE FROM COMBUSTIBLES
3) SECURE GAS LINE PER CODE
UNIT 2:
1) FIRE BLOCK THROUGHOUT
2) MID BEARING WALL NOT TO CODE DBLE TOP PLATE OR STUDS SINGLE TOP PLATE WITHIN 1 1/2" FROM RAFTERS AND CLIP RAFTERS
3) NOTE 3 & 2 FROM PREVIOUS
4) PROVIDE 1" CLEARANCE WATER HEATER FLUE FROM COMBUSTIBLES
05/11/2009 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLETE SET OF APPROVED DRAWING REQUIRED
2) DEMENSIONED FLOOR PLAN, ELECTRICAL, PLUMBING, GAS AND MECHANICAL PLAN REQUIRED
3) SUBMIT 2 COMPLETE SETS TO DEVELOPMENT SERVICES DEPT. FOR APPROVAL
4) OBTAIN RECONNECT PERMIT AND PROVIDE GFI OUTLET AT SERVICE PANEL FOR TEMP POWER
5) ALL WORK TO BE DONE BY LICENSED CONTRACTOR FOR RENTAL PROPERTY