Permit: T06CM06535

Parcel: 12308002B

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
06/05/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
05/28/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
NO ADDRESS POSTED!!!
1. AT WATER CLOSET - FLUSH HANDLE TO BE ON THE WIDE SIDE - BOWL TO BE HANDICAPPED
2. URINAL OVERFLOW TO BE NO HIGHER THAN 17" AFF FROM TOP OF URINAL TO CRITICAL LEVEL TO BE A MINIMUM OF 6"
3. ALL DRAINAGE PIPING TO HAVE A SMOOTH INTERIOR
WATER WAY
4. REQUIRE 15" FROM SIDE WALL TO CENTER OF URINAL
5. WE REQUIRE A MINIMUM OF 3 CLIPS ON FRONT AND BACK OF SINK AND 2 CLIPS ON EACH SIDE
6. DISHWASHER DRAIN HOSE TO BE SECURED WITHIN 2" OF DRAIN BOARD HEIGHT
7. ICE MAKER REQUIRES HAMMER ARRESTOR - URINAL REQUIRES A HAMMER ARRESTOR

CONTINUED "NOT READY" WILL RESULT
IN A REINSPECTION FEE