Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM06518
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/14/2007 | FRAMING | Approved | IVRS - Inspection :* | |
03/13/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WATER HEATER VENT NOT FIXED |
|
03/12/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIRESTOP AT HUTCH CHASE-LIVING ROOM NEEDS TO BE SEALED 2) 3" SAN-TEE AT KITCHEN PROTRUDING OUTSIDE OF WALL 3) CHASE MASTER BEDROOM NEEDS FIRESTOP 4) A/C VENT DUCT BOOT-NEEDS TO BE SQUARED UP AT MASTER BATH 5) B-VENT TO W/H GOING THROUGH TRUSSES NEEDS MORE PITCH-CANNOT BE FLAT 6) FIX 2" HOLE IN STUCCO MESH AT ENTRY ARCHWAY |
|
03/09/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. FIRESTOP 12" ROUND DUCT IN CHASE FROM 2ND FLOOR TO ATTIC BETWEEN WEST BEDROOMS. |