Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM06513
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/01/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
02/28/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REPAIR ON A05 TRUSS NOT COMPLETED LIKE ENGINEER FIX CALLS FOR 2) SPALDING ON MAS STRAP AT GARAGE-WILL CHECK AT INTERMEDIATES 3) GABLE ? BLOCKING STILL MISSING A35 4) WILL REFEE NEXT TIME |
|
02/27/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SHEAR PANEL CORNER NEEDS DBL STUD AT REAR OF HOUSE 2 PLCS BOTH CORNERS 2. SHEAR PANEL GARAGE NEEDS DBL STUD AT CORNER 3. SPALDING ON MAS STRAP GARAGE 4. BROKEN TRUSS - A05 AT GARAGE - NEED ENGINEER FIX 5. GABLE TRUSS BLOCKING MISSING A35 6. STRAPS MISSING GABLE END WALL 7. CLIP 3PT BEARING TRUSS AT PATIO 8. NO LADDER TO ACCESS ROOF 9. NEED RSP4 CLIP AT FRONT CORNER OF HOUSE |