Permit: T06CM06512

Parcel: 141330090


Addresses:

8470 S HUNNIC DR


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM06512

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
04/20/2007 FRAMING Approved IVRS - Inspection :*
04/17/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIRE STOP AT HALL CAHSE 3/4" OR DBL OSB-CHECK ALL CHASES
2) FIRE STOP AT CHASE AT DEN-SEAL AROUND DUCT VENT
3) NEED PROTECTION PLATE AT STAIRS AND HALLWAY 2ND FLOOR
4) PEX LINE AT DINING ROOM NEEDS TO BE RE-ROUTED/NEEDS 1.5" PROTECTION
5) PROTECTING PLATE AT VENT PIPE UNDER STAIRS
6) PROTECTION PLATE ON VENT MASTER BATH
04/13/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
03/28/2007 FRAMING Not ready for Inspection IVRS - Inspection :*