Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T06CM06448
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/28/2012 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
06/26/2012 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* WRONG LABELING AT CIRCUIT PANEL IN BEDROOM FOR FAN COILS WATER HEATER IN GARAGE REQUIRES A DISCONNECTIONG MEANS WITHIN SITE OF WATER HEATER FILL IN HOLES IN PANEL DEAD FRONT PROVIDE HOSE CLAMPS AT BAR SINK USE LISTED TAPE ON LINE SETS |
|
06/08/2012 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
05/23/2012 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* DO NOT USE FLEX COPPER ON THE T&P DRAIN LINE PROVIDE AN OVERFLOW SENSOR IN FAN COILS EXTEND VENT IN CONDENATE TRAP ABOVE DRAIN PAN PROVIDE A PROTECTIVE COATING ON EXPOSED ARMAFLEX T STAT WIRE AT CONDENSORS TO BE IN CONDUIT CIRCUIT BREAKERS TO LARGE FOR CONDENSORS. DO NOT USE WHITE WIRE FINISH INSTALLING 2ND A/C SYSTEMS CIRCUIT BREAKERS TO LARGE FOR FAN COILS. CANNOT FIND BREAKER FOR 2ND FAN COIL PLUMBING NOT COMPLETE FINISH ALL WORK PRIOR TO RESCHEDULING INSPECTINS |