Date Description Inspector Results Comments
04/19/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
04/12/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TWO NAILS IN EACH WIND BRACE AT PLATES
2) NO NAILS IN OSB UNDER 2 X 6 KICK
3) STRAP REAR PORCH BEAM
4) WRONG NAILS IN P.A.'S
5) RAT RUN MISSING COL. C02 C03
6) BROKEN STUD
7) SHIM REAR GABLE CONTINOUS BEAR
8) BLOCK OSB AT GARAGE TURNED LONG DIMENSION
9) SHIM HIPS AT TOWER