Permit: T06CM06417

Parcel: 12513002B


Addresses:

3200 E SPEEDWAY BL


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T06CM06417

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
03/27/2008 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
APPROX. 400' OF SCREEN WALL @ 3'-48';
TRASH ENCLOSURE @ 8'
STORAGE AREA @ 13' -- OK TO GROUT
03/13/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
ALL EXTERIOR WALLS & POPOUTS TOPPED OUT
03/12/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
(3/4" ANCHOR BOLTS IN PLACE)
SOUTH & EAST WALLS @ 24'8" (GROUTED);
NORTH WALL @ 23'4" -- OK TO GROUT
03/10/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH WALL & EAST WALL @ 20'8"; STRAPS & LEDGER BOLTS IN PLACE: OK TO GROUT PROGRESS AREAS
03/06/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
WEST WALL @ 16'8" - LINE E/1 TO E/4 -- OK TO GROUT
03/05/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH WALL @ 18'
MASONRY LINTELS;
LINE A/1 TO E/1 OK TO GROUT
03/03/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SOUTH WALL C.5/4 TO A/4 @ 16'8"
EAST WALL A/1 TO A/4 @ 16'8"
LEDGER BOLTS PLACED AS PER DETAIL #6 PAGE S3.1
NORTH WALL A/1 TO B/1 - OK TO GROUT PROGRESS AREAS
02/28/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH WALL, LINE A/1 TO D.5/1 @ 12'8" -- OK TO GROUT
02/27/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
WEST WALL LINE E/1.5 TO E/4 @ 12'8",
SOUTH WALL LINE D.5/4 TO E/4 @ 12'8" -- OK TO GROUT
02/26/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SOUTH WALL A/4 TO D/4 @ 8'-12' --- OK TO GROUT
02/25/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EAST, NORTH & WEST WALLS @ 8'8" - ENTRY COLUMNS @ 8'8"
OK TO GROUT PROGRESS AREAS
02/21/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH WALL @ 0"-4' (EXCEPT MAIN ENTRY); WEST WALL @ 0"-4'; SOUTH & EAST WALLS @ 4'-8' (0"-4' GROUTED AS PER SPECIAL INSPECTION) -- OK TO GROUT PROGRESS AREAS
02/15/2008 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELED - RAINED OUT
02/13/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CONTINUOUS STEM WALL @ 16"
OK TO GROUT