Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM06402
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/03/2007 | FRAMING | Approved | IVRS - Inspection :* | |
09/28/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SISTER STUDS NEXT TO OVER NOTCHED STUDS IN FURNACE ROOM 2) BLOCK RETURN AIR BOOT 3) FILLS OVER CUT FIRE BLOCKS WITH FIRE FOAM OR ROCK WOOL 4) SHEETROCK BACKING FOR VENT PIPES MASTER LAVS 5) RECEPTACLE REQUIRED RIGHT OF FRIDGE 6) INSTALL BOX FOR DBL OVEN 7) AS MENTIONED AT PRESLAB, VENT GAS PIPE FROM KITCHEN TO OBVIOUS LOCATION 8) COMPLETE VACUUM SYSTEM AND INSTALL NAIL STOP PLATES 9) NAIL OFF FHA STRAPS AT TO PLATE MASTER CLOSET LINE SETS 10) NEED 12" CLEAR PEX TO CAN LIGHT AT DESK 11) MOST WATER SOFTNERS PUMP WASTE MAX 8' HIGH 12) 2" PIPE OUT OF WALL IN POWDER ROOM 13) GAS CONTROL VALVE FOR FIRE PLACE NOT ACCESSIBLE IN L/R 14) CONNECT SUPPORT STRAPS FOR CHIMNEY MASTER |
|
08/22/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) WALL OK TO GROUT IN COURT YARD |