Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM06402

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
10/03/2007 FRAMING Approved IVRS - Inspection :*
09/28/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SISTER STUDS NEXT TO OVER NOTCHED STUDS IN FURNACE ROOM
2) BLOCK RETURN AIR BOOT
3) FILLS OVER CUT FIRE BLOCKS WITH FIRE FOAM OR ROCK WOOL
4) SHEETROCK BACKING FOR VENT PIPES MASTER LAVS
5) RECEPTACLE REQUIRED RIGHT OF FRIDGE
6) INSTALL BOX FOR DBL OVEN
7) AS MENTIONED AT PRESLAB, VENT GAS PIPE FROM KITCHEN TO OBVIOUS LOCATION
8) COMPLETE VACUUM SYSTEM AND INSTALL NAIL STOP PLATES
9) NAIL OFF FHA STRAPS AT TO PLATE MASTER CLOSET LINE SETS
10) NEED 12" CLEAR PEX TO CAN LIGHT AT DESK
11) MOST WATER SOFTNERS PUMP WASTE MAX 8' HIGH
12) 2" PIPE OUT OF WALL IN POWDER ROOM
13) GAS CONTROL VALVE FOR FIRE PLACE NOT ACCESSIBLE IN L/R
14) CONNECT SUPPORT STRAPS FOR CHIMNEY MASTER
08/22/2007 FRAMING Not ready for Inspection IVRS - Inspection :*
1) WALL OK TO GROUT IN COURT YARD