Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM06372
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/08/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 03/07/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FROM LAST INSPECTION FULL HT STUD AT OVEN VENT STUD SPACING 16" ON CENTER. YOU DON'T HAVE IT 2) STRAP DROP AT LIVING ROOM FROM COMING DOWN STRAP TO TRUSSES 3) HEADER AT MSTR MECH NOT NAILED TO STUDS OR OSB PLEASE NAIL |
|
| 03/06/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) KITCHEN OVEN VENT, STUD REPAIR NEED FULL HT. STUD SISTERED IN 2) BANG PLATE CONDENSATE LINE 3) STRAP DROP AT FRONT ENTRY 12" X 12" DROP WITH RADIUS 4) SAFETY GLASS AT FRONT ENTRY 24" RADIUS 5) PLUMB CRIPPLES MASTER BAY WINDOW 6) MASTER BED, FHA STRAP AT SHOWER VENT BOTTOM PLATE BED SIDE 7) MASTER HEADER OFF, NAIL CUT STUD AT MECH DUCT |