Permit: T06CM06353

Parcel: 136261290

Inspection Status: Approved

Inspection History: PLUMBING - PRE SLAB

Date Description Inspector Results Comments
03/14/2007 PLUMBING - PRE SLAB Approved IVRS - Inspection :*
03/13/2007 PLUMBING - PRE SLAB Partial Approval IVRS - Inspection :*
03/09/2007 PLUMBING - PRE SLAB Not ready for Inspection IVRS - Inspection :*
1. SHALL CORRECTLY INSTALL WASTE & VENT PER PLAN
2. HORIZONTAL VENTING BELOW FLOOD RIM OF FIXTURES REQUIRE VENT TO BE TAKEN OFF DRAIN AT CONTROLLING OF DRAIN. NOTE: MINIMUM 45 DEG.
3. PROVIDE REDLINE ON SITE
4. PROVIDE TEST ON SYSTEM WITH DRY MATERIAL AS SHADING ON ALL PIPING