Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM06353

Parcel: 136261290

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T06CM06353

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
03/14/2007 PLUMBING - ROUGH, SOIL Approved WATER TEST WASTE & VENT & GREASE WASTE UNDERGROUND OK

WHEN REVISED APPROVED PLAN ON SITE FOR CHANGES & DELETION OF FLOOR SINK
03/13/2007 PLUMBING - ROUGH, SOIL Partial Approval 4" GREASE WASTE INSTALLED PER PLAN WATER TEST OK
1 PER CAP P-TRAP AT 3-COMP SINK UNDERGROUND AREA
4" SANITARY DRAINAGE WATER TEST OK
ALL AREAS EXCEPT 2" BRANCH SERVICE (2) FLOOR SINKS AT NORTHWEST SECTION TO BE VENTED CORRECTLY & RETESTED