Permit: T06CM06349

Parcel: 13348128F

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Permit Number - T06CM06349

Inspection Description - MECHANICAL - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/17/2007 MECHANICAL - FINAL Approved IVRS - Inspection :*
05/15/2007 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
1. PERMANENTLY I.D ALL EQUIPMENT ON ROOF WITH SUITE NUMBER & EQUIPMENT NAME OR NUMBER (WALK IN COOLER, WALK IN FREEZER, AC-1, AC-2, ETC.
2. MARK AC UNIT IN DATA PLATE W/PROPER HEAT STRIP INSTALLED & FUSE ACCORDINGLY.
3. PROVIDE A FRESH AIR INTAKE
4. PROVIDE AN AIR BALANCE REPORT
5. CLEAN THE TAR OUT OF THE VENT ON CONDENSATE TRAP.
VENT MUST BE DOWNSTREAM OF THE TRAP. TESTED DUCT SMOKE DETECTORS.