Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T06CM06329
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/25/2009 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 05/06/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CLOSET FLANGES OK |
|
| 03/18/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* PAN LINERS OK |
|
| 02/13/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* PIPE INSULATION OK WALLS AND CEILING OK TO COVER |
|
| 02/10/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* PEX W/90 PSI TEST OK TO INSULATE STANDARD TUBS W/TEST OK WILL INSPECT SHOWER PAN LINERS, GARDEN TUBS AND CLOSET FLANGES WHEN READY |
|
| 01/30/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. ROOF DRAIN TEST OK 2. WASTE & VENT IN WALLS TEST OK |
|
| 01/28/2009 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* DWV - CORRECT 1/4 BEND AND SAN-T RETEST PROVIDE LISTING FOR 3" C1 CLOSET FLANGES, IN VIOLATIONS OF SEC. 316.3.2 |