Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
Permit Number - T06CM06327
Inspection Description - MECHANICAL - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/08/2008 | MECHANICAL - INTERMEDIATE | Approved | IVRS - Inspection :* OK FOR SHEETROCK |
|
05/09/2008 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* - DO NOT REDUCE THE SIZE OF A CONDENSATE DRAIN - SUPPORT HORIZONTAL SECTIONS EVERY 4' - PROVIDE MIN. 1" CLEARANCE FROM COMBUSTIBLES AT WATER HEATER VENT - FIREPLACE VENTS SHALL BE A MIN. 4' AWAY FROM A DOOR OPENING - OK TO SHEETROCK RESTROOM CEILINGS |