Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06CM06308

Parcel: 123090210


Addresses:

2919 E MABEL ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
12/27/2006 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
12/22/2006 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. REMOVE ALL ABANDONED PIPE AT METER.
2. CONNECT ALL REMAINING PIPE & PROVIDE TEST.
3. SECURE 1/2 GAS LINE AT WALL.
4. SECURE GAS LINE BEHIND CLOTHES DRYER.
5. PROVIDE GAS SHUT OFF VALVE IN AN ACCESSIBLE LOCATION FOR WALL HEATER.
12/21/2006 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*