Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/22/2008 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 04/18/2008 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) PENDING CERTS |
|
| 02/08/2008 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GRADING AT FRONT OF HOUSE NOT TO CODE. NEED 4" AT WEEP 2) NEED LANDING AT ENTRY DOOR TO BACK OF GARAGE 3) NEED LANDING AT ALL EXTERIOR DOORS 4) A/C HANDLER BEHIND GARAGE HAS EXTRA COPPER PIPE, WHERE DOES IT GO OR HAS IT BEEN DELETED 5) DRAW HOSE FOR DISHWASHER NEED TO BE DETACHED TO BACK OF CABINET AND LIFT FOR AIR GAP 6) SEAL HOLES IN MECHANICAL ROOMS IN CEILING |
|
| 01/22/2008 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MASTER ARC NOT TRIPPING 2) ATTACH SUB-PANEL GROUND BAR TO PANEL JACKET 3) SEAL TOILETS TO FLOOR 4) NEED LIGHT DIFFUSERS IN CLOSETS 5) NEED HOUSE NUMBER 6) NEED FINAL GRADE |