Permit Number - T06CM06284

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Partial Approval

Date Description Inspector Results Comments
01/11/2007 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) PENDING AS BUILTS FOR BRACED PANELS
01/08/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) RETRO FITS REQUIRED BRACED PANELS ? 4'-0"
2) REVISION FOR ADDED WINDOWS AND DOORS DOES NOT ALLOW FOR 4'-0" BRACED PANELS ON PLAN. SUBMIT AS BUILTS FOR APPROVAL FOR HOLDOWNS. TO MANY WINDOWS AND DOORS ADDED TO ALLOW BRACED PANELS
3) MISSING H2.5 CLIPS TJ'S TO BEARING WALLS
4) STRAP HEADERS PER PLAN CFHA22
5) 6" ON CENTER ALL BRACED PANEL EDGES