Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
Permit Number - T06CM06274
Inspection Description - MECHANICAL - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/13/2007 | MECHANICAL - INTERMEDIATE | Approved | IVRS - Inspection :* SUPPLY & EXHAUST IN RESTROOMS OK TO COVER CONDENSATE DRAINS OK |
|
07/10/2007 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CORRIDOR DAMPERS MUST BE COMBINATION FIRE/SMOKE NOT REQUIRED WHERE 26GA DUCT ON PASSES THROUGH THE FIRERATED ASSEMBLY WITH NO DUCTS INTO CORRIDOR SUSPENDED ROUGH DUCT. OK TO PROCEED |