Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/12/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 07/11/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 07/09/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. INSTALL ALL BACKFLOW DEVICES PER PLAN AND AS REQUIRED FOR APPLIANCES WITH DIRECT WATER CONNECTION THAT ARE NOT LISTED OR HAVE PROOF OF 1" AIR GAP. 2. PROVIDE MINIMUM FALL ON 3" 3-COMP SINK GREASE DRAIN PIPE 3. ALL CLEANOUTS TO HAVE FACTORY TAPPED PLUGS & MACHINE SCREWS FOR CLEANOUT COVERS. 4. ALL APPLIANCES TO BE INSTALLED 5. PROVIDE BACKFLOW CERTIFICATIONS 6. INSTALL HEAT TRAPS FOR WATER HEATER PER PLAN AND INSULATE 8' INLET & 8' OUTLET PIPING OF WATER HEATER PIPING PER 2003 ENERGY CONSERVATION CODE 7. VENTS THRU ROOF TO BE LATEX PAINTED FOR SUN EXPOSURE. 8. PROVIDE TRAFFIC RATED CLEANOUT COVER FOR TRAFFIC AREA |