Permit: T06CM06263

Parcel: 140553650

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/12/2007 FRAMING Approved IVRS - Inspection :*
03/09/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. REAR GABLE LATHE NOT COMPLETE (REPEAT)
2. NO DWV WATER TEST (REPEAT)
3. M/BATH EXHAUST FAN NOT WIRED
4. ANCHOR BOLTS REQUIRED WITHIN 12" OF SHEAR WALL PLATE SPLICE.

OK TO INSULATE
03/07/2007 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) LATHE NOT COMPLETE REAR GABLE
2) ANCHOR BOLTS MISSING THROUGHOUT
3) NO DWV TEST
4) NO POTABLE WATER TEST
5) LAV DIRTY CANNOT EXCEED 1/2" TO VENT
6) WATER LEAKS
7) NO A/C CONDENSATE DRAIN
8) STOPPED INSPECTION
9) TOO MANY ITEMS