Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/26/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 02/23/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL 2 NAILS TOP AND BOTTOM WIND BRACING 2) CHECK REAR SHEAR NAILS INTO PLUMBING PIPE4 AT BOTTOM PLATE-NEEDS BANG PLATE 3) INSTALL WIND BRACING EACH CORNER BOTH WAYS AND MAXIMUM 25' OF RUN (TRUSS BRACE SAME) 4) CHECK ALL SHINERS ROOF NAILING-RENAIL 5) GARAGE SHEARWALL TRANSFER INCOMPLETE 6) 6D AT 8" CENTERS REQUIRED THRU ROOF SHEATHING INTO BLOCKING AT EXTERIOR TRUSS BEARING 7) SAME WITH GARAGE ROOF SHEAR TRANSFER 8) STOPPED INSPECTION |