Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/21/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 03/15/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 2ND FLOOR CLOSET REAR NAIL BOTTOM PLATE 8" ON CENTER 16D'S 2) PROTECT ROMEX AT KIT COUNTER 3) NEED POTABLE H20 AND DWV WATER TESTED |
|
| 03/12/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) FLAT VENT TO BE ON SAME LEVEL AS P-TRAP 2) ANCHOR BOLTS PER SCHEDULE 1ST FLOOR 3) 2ND SHEARWALLS, NAIL AT 8" ON CENTER 4) MISSING NUT AT H.D. KIT. 5) ADD CRIPPLES, UNDER ROOF SUPPORT GIRDER TRUSS AND GLU LAM BEARING AT STAIR 6) LOOSE NUTS AT HPAD 8 7) NEED POTABLE H20 AND DWV TEST |