Permit: T06CM06262

Parcel: 141315840

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM06262

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
03/21/2007 FRAMING Approved IVRS - Inspection :*
03/15/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 2ND FLOOR CLOSET REAR NAIL BOTTOM PLATE 8" ON CENTER 16D'S
2) PROTECT ROMEX AT KIT COUNTER
3) NEED POTABLE H20 AND DWV WATER TESTED
03/12/2007 FRAMING Partial Approval IVRS - Inspection :*
1) FLAT VENT TO BE ON SAME LEVEL AS P-TRAP
2) ANCHOR BOLTS PER SCHEDULE 1ST FLOOR
3) 2ND SHEARWALLS, NAIL AT 8" ON CENTER
4) MISSING NUT AT H.D. KIT.
5) ADD CRIPPLES, UNDER ROOF SUPPORT GIRDER TRUSS AND GLU LAM BEARING AT STAIR
6) LOOSE NUTS AT HPAD 8
7) NEED POTABLE H20 AND DWV TEST